LuaCAD Help

Block Library reference

The buttons of the palette

The highlighted button Insert … (in the color of the plug-in) puts something new into the drawing; all other buttons change, check or output. Every button and every tile shows a tooltip when you hover over it. A button with a crosshair picks a value from the drawing, an "i" opens an explanation.

Top: title bar, switch, search, tabs

ElementEffectMore
"i" in the title barWhat the shown page does, with "More in the online help".The pages of the palette
GearThe menu of the plug-in.The gear menu
2D / 3D switch, line below with "i"What the palette shows and what is inserted.2D or 3D
SearchFilters the tiles and the Current Drawing list (name, folder).Finding blocks
Tabs Library, Fixtures, star, Recent, Current DrawingThe pages.Pages

Library page

ElementEffectMore
Line above the tree with "i"Standard blocks read-only, custom blocks in your own folders.Standard and custom blocks
Folder tree (right-click: maintain folders)Choose a folder; the number counts the matching blocks.Finding blocks, Maintaining folders
Bar below tree and tilesDrag the height; double-click = default.Finding blocks
Tiles (click, double-click, star, right-click)Select and preview, insert, favorite, shortcut menu.Finding blocks, Shortcut menu
Line below the tilesNumber of blocks; how many exist only in the other mode.Finding blocks

Fixtures page

ElementEffectMore
TilesAll fixtures (blocks from folders named Apparate), without a tree.Standard fixtures
Detect fixtures in the plan and insert … (with "i")Find fixtures in the architect's floor plan and place the standard fixtures.Detecting fixtures in the plan
Below: Connectors, Drainage routingConnector set and routing of the next fixtures.Connector set, Routing

Favorites page

ElementEffectMore
Tiles with a filled starThe favorites from all folders; star = take out.Favorites

Recent page

ElementEffectMore
TilesThe blocks inserted last, the newest first, at most 20.Recent

Current Drawing page

Button / areaEffectMore
List "Inserted blocks of this drawing"All blocks of the library, multiple selection.The blocks of the drawing
AllSelect all blocks of the list.List
From drawingTake over the blocks selected in GstarCAD (without a selection: select now).List
ShowSelect the chosen blocks in the drawing and zoom to them.List
Common properties, Apply to n block(s)Write values into all selected blocks.Changing several
Extract (table or CSV), Extract as ExcelCount and output the blocks of the drawing.Block extract
Extract across the project …, Extract across xrefs …Across several drawings.Across several drawings
Reload blockClick a block: read its DWG again.Reloading a block
ClashesRule set, scope, Check, list.Clashes

The next block

ElementEffectMore
Selected block (name, origin, factor)What is inserted.Inserting a block
Connectors (with "i")Connector set; only for fixtures with several sets.Connector set
Properties of the next block (expandable)Property fields for every following block.Properties
Drainage routing (with "i")Drain of the next standard fixtures; fixtures only, 3D only.Drainage routing
Elevation and rotation: elevation, level, distance from, value, check mark, crosshair, rotation (degrees)Elevation (3D only) and angle of the next block.Elevation and rotation
Insert connectors only (with "i")Instead of the fixture only its connectors.Connectors only
Insert …Insert the selected block at the cursor.Inserting a block
FooterMessages of the palette (folder created, factor set, value checked …).Notes

Shortcut menus

WhereEntryEffect
TileInsertSelect and insert right away.
TileAdd to favorites / Remove from favoritesLike the star.
TileOpen DWG (edit, define connectors)Open the DWG in GstarCAD.
TileShow in ExplorerOpen the folder with the DWG highlighted.
Folder in the treeNew folder …Create a subfolder (own folders only).
Folder in the treeRename …Rename the folder (own folders only, not the root).
Folder in the treeDelete …To the recycle bin after confirmation (own folders only, not the root).
Folder in the treeScale factor … (now n)Set the factor of the folder.
Folder in the treeShow in ExplorerOpen the folder.
Block in the drawing › LuaCADShow block propertiesAll fields of the block to the command line.
Block in the drawing › LuaCADChange connector setSwap the connector set of a fixture.
Drawing › LuaCADBlock LibraryOpen the palette.

Unavailable entries are gray; their tooltip says why.

All keys at the cursor

The same key means the same in every plug-in. Which one applies right now is shown by the action bar; Shift and Ctrl are never assigned at the cursor (they belong to the CAD).

KeyMeaning in the Block Library
Spaceshow the base points (insertion point, corners, midpoints, connectors), a click takes one; when rotating with the mouse: 45° increment on/off
Gfree base point: click any point on the block with object snap – also in the choice of base points
AEnter distance dialog box: amounts X/Y, base point, rotation, elevation (3D only)
Rrotate with the mouse
Dtype the rotation angle (degrees)
Wpick the angle – always two clicks; the front lies to the left of the direction
Mmirror left/right; fixtures: cold water stays on the right
← / →rotate by 45°
Enterdone – back to the palette
Escback to the palette; in a choice (base point, angle): back without a change

In the block wizard and when detecting in the plan, Enter (confirm or "none") and Esc (cancel) apply.

The gear menu

The gear menu of the Block Library open: wizard, fixtures in the plan, folders, systems of fixture connectors (1), scale factor for the folder 'Standard blocks', drawing units, reload library (2), preview window (3), properties (4), layers (5), help and info (6), getting started (7)
The gear menu of the Block Library open: wizard, fixtures in the plan, folders, systems of fixture connectors (1), scale factor for the folder 'Standard blocks', drawing units, reload library (2), preview window (3), properties (4), layers (5), help and info (6), getting started (7)
EntryEffect
New block / fixture from the drawing (wizard) …The block wizard – see Creating a custom block.
Detect fixtures in the architect's plan and insert …Like the button on the Fixtures page – see Detecting fixtures in the plan.
Folders …The own folders of the library – see Folders for blocks.
Systems of fixture connectors …Which system the connectors of the standard fixtures get – see Systems of fixture connectors.
Scale factor for folder '…' …Only on the Library page with a folder selected – see Scale factor.
Drawing units …In which units new parts are created and fields show lengths – for all plug-ins, see Drawing units.
Reload libraryRead all folders again – see Reloading the library.
Preview window › Show, HideThe preview window next to the palette; Show also brings back a closed one.
Properties › Property fields …Which fields exist – see Property fields.
Properties › Author …The name in lists, IFC and the clash list – for all plug-ins.
Layers › Create all layers of this plug-inCreates the layers of the standard blocks that are missing; existing ones stay as they are.
HelpOpens this online help of the Block Library in the browser.
InfoVersion of LuaCAD and contact.
Getting started activeCards of the pages and the help before inserting for this plug-in on or off.
Show getting startedThe tip assistant leads step by step through the shown page.

The LuaCAD settings (for all plug-ins) are on the ribbon › LuaCAD tab › Info – see Getting started. Systems, levels and system elevations are maintained in the plug-ins that draw pipes (for example Piping 3D); the Block Library reads the levels only for the elevation from level.

Dialog boxes

Insert fixtures automatically

Picture coming soonThe dialog box "Insert fixtures automatically": heading with the number of locations (1), per row check box, number, standard fixture, how detected, Show (2), the line about the warning sign (3), All / None (4), A fixture is missing? with type and Click an example (5), Insert n fixtures / Cancel (6)

Opens after choosing the area (Fixtures page › Detect fixtures in the plan and insert …); it is placed on the right of the main window so that the plan with the numbers stays visible. At the top an "i" with the explanation.

ElementEffect
Heading"n location(s) – the numbers are in the plan: green = will be inserted, gray = not." Without a find: "No fixture was detected in the plan …"
Check boxInsert this location. Checking it with "– do not insert –" gets the suggested standard fixture.
NumberThe same number as in the plan.
Standard fixture (list)Which standard fixture is inserted; "– do not insert –" takes the location out. Another choice is remembered for the next plan. Focus on the list highlights the location in the plan.
How detectedBlock name or shape; ⚠ = direction not recognized from a wall. Tooltip: origin and direction.
ShowZooms to the location.
All / NoneSet or clear all check boxes.
A fixture is missing? – type, Click an example …Catch up on an undetected type with an example – see Click an example.
Insert n fixtures (Enter)Place the checked standard fixtures; gray as long as none is checked.
Cancel (Esc)Insert nothing.

Block wizard

Picture coming soonThe Block wizard dialog box: line "Detected: …" (1), Block with name, store in, subfolder, type / code with "i", fixture type (2), default values (3), Create connectors with drainage, routing, template horizontal, in-wall carrier code, cold water, hot water, DN (4)

Opens in the block wizard after the selection and the insertion point. At the top an "i" (rules for fixtures), below it "Detected: n solid(s) (3D), n 2D objects, n connector(s) of the plug-ins." Every field: Block wizard in detail.

AreaContent
BlockName, store in (only folders you may write to – never the standard blocks), subfolder, type / code, fixture type.
Default values (property fields)Description, manufacturer, article number, type, W × D × H (measured).
Create connectors (with "i")Drainage with routing, template horizontal, in-wall carrier code; cold water, hot water, DN.
OK / CancelOK checks name and storage folder, asks whether an existing DWG is overwritten; then the clicks for the connectors. Cancel saves nothing.

If there is no folder you may write to, it says in red: "No writable root – create a folder of your own in the palette under gear menu › Folders."

Folders for blocks

The dialog box "Block Library – Folders for blocks": the list, here with the entry "Custom blocks" (1), Add, Add subfolders, Remove (2), Selected folder with name and path (3), the contents (4), OK / Cancel (5)
The dialog box "Block Library – Folders for blocks": the list, here with the entry "Custom blocks" (1), Add, Add subfolders, Remove (2), Selected folder with name and path (3), the contents (4), OK / Cancel (5)

Gear menu › Folders …. On the left the list of your folders (with path; "not found" if the folder is missing; "supplied part" for supplied ones), below it Add, Add subfolders, Remove. On the right Selected folder: Name (as it appears in the tree) and Path (type it or choose it with the button), below it what it contains. OK saves the list and the selected entry, as does a double-click on an entry; Cancel discards. Every field: Folders in detail.

Systems of fixture connectors

The dialog box "Block Library – Systems of fixture connectors": introduction (1), columns Connector (role) and System (2), per role list and color field (3), the explanation of "automatic" and the note (4)
The dialog box "Block Library – Systems of fixture connectors": introduction (1), columns Connector (role) and System (2), per role list and color field (3), the explanation of "automatic" and the note (4)

Gear menu › Systems of fixture connectors …. Per role (cold water, hot water, recirculation, heating supply, heating return, gas) a list with "(automatic: …)" and all Piping 3D systems, on the right the color field of the choice. OK saves, Cancel discards. If Piping 3D has no systems, a red note appears. Every setting: Systems of fixture connectors in detail.

Property fields

The Property fields dialog box on the Block Library tab: tabs Common and one per plug-in (1), the list of the fields – still empty here because there is no field of your own (2), New field / Remove / Export / Import (3), the attributes of a field (4)
The Property fields dialog box on the Block Library tab: tabs Common and one per plug-in (1), the list of the fields – still empty here because there is no field of your own (2), New field / Remove / Export / Import (3), the attributes of a field (4)

Gear menu › Properties › Property fields … – the same dialog box in all plug-ins, opened on the Block Library tab. It decides which fields blocks and fixtures have. On the left the fields of the tab (default fields gray with a lock – hide only), below them New field, Remove (only a new field not yet saved), Export … and Import … (an XML file, for example for the whole office). On the right the attributes of the selected field. OK saves for all plug-ins; the palette rebuilds its fields afterwards. Every attribute: Property fields in detail.

Scale factor

The Scale factor dialog box: "Insert blocks from 'Standard blocks' with this factor (1 = original size):" (1), the field (2), the note (3), OK / Cancel (4)
The Scale factor dialog box: "Insert blocks from 'Standard blocks' with this factor (1 = original size):" (1), the field (2), the note (3), OK / Cancel (4)

Right-click a folder › Scale factor … or gear menu › Scale factor for folder '…' …. A field for the factor (you may calculate), below it the note about subfolders and fixtures. An invalid value: "Please enter a number greater than 0 (for example 50 or 1/50)."

New folder, rename folder

Right-click a folder › New folder … or Rename …. The question names the folder, the field is preset with a free name ("New folder", "New folder 2" …) or with the previous one; when renaming, the note "Favorites and recent move along …". OK checks the name – if it is invalid or already exists, the reason appears in red below. See Creating, renaming, deleting folders.

Enter distance (key A)

Picture coming soonThe "Enter distance" dialog box: amounts X and Y (1), the 3 × 3 field with the base points of the block (2), rotation (3), elevation (4), OK (5)

Opens at the cursor with A. X and Y are amounts in the axes of the block (X along the wall, Y into the room), 0 and 0 = no distance; the 3 × 3 field shows the base points of the block – a click chooses one, the side of the distance follows it. Plus Rotation and – in 3D only – Elevation (absolute, from level or free with the mouse). At the top an "i". After OK click the reference point. See Inserting at a distance.

Drawing units

The Drawing units dialog box, opened from the gear menu of the Block Library: the choice of units – automatic or always mm, cm, dm, m (1), OK (2)
The Drawing units dialog box, opened from the gear menu of the Block Library: the choice of units – automatic or always mm, cm, dm, m (1), OK (2)

Gear menu › Drawing units … – the same dialog box in all plug-ins: in which units fields show lengths and new parts go into the drawing (automatic, mm, cm, dm, m). A block stays in the units of its DWG and goes in with the matching factor. Details: Drawing units.

Confirmations

QuestionWhenChoice
Delete folderDelete … on a folder of your own; states the number of DWGs and subfolders.To the recycle bin · Cancel
<list>: n row(s) – where should it go?Block extract, as long as the list options say "Ask every time".Into the drawing · Into a file · Cancel
Required fields missingBefore the extract, if a required field is empty.Output anyway · Show parts
The connector … disappears in the new connector setChanging the connector set, a pipe ends at a disappearing connector.Reconnect to … · Leave pipe open · Cancel
"…" already exists. Overwrite?Block wizard, the DWG already exists.Yes · No
Remove the folder "…" from the list?Folders for blocks › Remove.Yes · No

Every setting in detail

Here is every setting of the Block Library – in the palette, in the gear menu and in the dialog boxes – with its effect, the default value and an example. Values in the palette apply only to blocks you insert afterwards and are saved right away (also across a restart). A "–" in the "Default" column means: the value depends on the library or the data. Number fields calculate ("600+400" becomes 1000).

Top of the palette

SettingWhat it doesDefaultExample
2D / 3D switch3D: show blocks with solids and insert them with solids at their elevation. 2D: show blocks with 2D parts and insert them in the drawing plane, connectors as marks. Filters tree, tiles, favorites, recent and search; a selected block that does not exist in the new mode is deselected.3D2D for a floor plan with Piping 2D
SearchEvery typed word must occur in the name, the folder path or the name of the library; upper/lower case and umlaut spelling do not matter. Applies on all pages.empty"shower 90"
TabThe page shown; remembered.LibraryFixtures

Library page

SettingWhat it doesDefaultExample
Selected folder (tree)Which blocks the tiles show (the folder with all subfolders). Expanded folders stay open when reloading.the first root (standard blocks)Plumbing › Manifolds
Height of the folder treeDrag the bar below it; double-click = default.130 (60–900)300 for many folders
Height of the tilesDrag the bar below it; double-click = default. On the Current Drawing page a fixed height applies.236 (100–1400)500
Favorite (star on the tile)Adds the block to the favorites or takes it out.none–

Fixtures, Favorites and Recent pages

These pages have no settings of their own apart from the tiles; switch, search and the "next block" area apply. The Fixtures page shows all blocks from folders named Apparate (custom ones too), Recent at most 20 blocks.

Current Drawing page

SettingWhat it doesDefaultExample
Selection in the listWhich blocks Show, Common properties and Apply affect (Ctrl/Shift-click for several). Stays after applying.noneall toilets of a level
Common properties (per field)A new value for all selected blocks; an unchanged field stays as it is per block. Shown are the property fields with "always on all parts" for blocks/fixtures and the dimensions.equal value or empty (gray)room "Bath 2.01"

The next block

SettingWhat it doesDefaultExample
Selected blockThe block that Insert … places; remembered.the last selected, otherwise the first matchingLavatory 60
ConnectorsThe connector set of the selected fixture; remembered per fixture, also applies to detecting fixtures in the plan. Only for fixtures with several connector sets.A (default set)B – valve on the side wall
Properties of the next blockThe fields with "ask before inserting" for blocks; every value goes to every following block, ahead of the defaults of the DWG. Empty = default of the DWG. Collapsed, the heading states how many are filled in.collapsed, emptyconstruction phase "B"
Drainage routingThe drain of the next standard fixtures: by fixture type (default) = toilet, lavatory, urinal, bidet into the in-wall carrier, bathtub, shower, appliances, sink below ceiling / in the floor; In-wall carrier or Below ceiling / in the floor for all. Gray for custom fixtures; fixtures in 3D only.by fixture type (default)below ceiling / in the floor in an old building without carrier
Elevationsee Elevationabsolute elevation, 0from level, FF, 0
Rotation (degrees)The angle at which the next block hangs at the cursor; applies when leaving the field, values over 360° are converted.090
Insert connectors onlyFor fixtures only the connectors with a marker; other blocks come complete. Applies in 2D and 3D and to detecting fixtures in the plan.offan architect's plan with drawn fixtures

Elevation

SettingWhat it doesDefaultExample
Elevationabsolute elevation = the Z coordinate; from level = level, reference level and value from it; free = the elevation of the clicked point (object snap takes the elevation of a part), then without a value. Switching keeps the elevation. 3D only.absolute elevationfrom level
LevelOnly with from level: its reference levels apply – preset with the level of the drawing.level of the drawing1st floor
Distance fromThe reference level TOS, BOS, FF or FC; its elevation in the chosen level in brackets.–FF
ValueWith absolute elevation the Z coordinate, from level the value from the reference level (negative = below). Applies right away; while inserting, a new number applies from the next insertion (at the cursor: A). The check mark and Enter take it over.00
Crosshair (pick elevation)Click a point with object snap – its elevation applies, with from level as the value from the chosen reference level, in the level of the point.–the top of a pre-wall

Levels and their reference levels are maintained in the project or in the gear menu of a piping plug-in – see Elevations and reference levels.

Gear menu › Folders

SettingWhat it doesDefaultExample
List of foldersWhich folders of your own appear in the tree, in this order below the standard blocks.Custom blocks (AppData\Roaming\LuaCAD\Bibliothek\Bloecke)an office folder on the server
NameWhat the folder is called in the tree; the path stays.the last part of the path"Office – plumbing"
PathThe folder on disk, typed or chosen; UNC paths too.–\\Server\CAD\Blocks
Selected entryOn OK the selected folder – the block wizard and saving custom blocks use it first if it is writable.the first–
Add subfoldersEach subfolder of the selected entry becomes an entry of its own (at most 100).––

Gear menu › Systems of fixture connectors

SettingWhat it doesDefaultExample
Cold waterThe system of the cold water connectors of new standard fixtures (and free pipe connectors of this role).automatic (reduced-pressure domestic cold water)domestic cold water at mains pressure
Hot waterthe same for hot waterautomatic–
Recirculationthe same for recirculationautomatic–
Heating supply, heating returnthe same for heating connectorsautomatica system of your own "Radiators supply"
Gasthe same for gasautomatic (natural gas)–

"automatic" takes the default system of the role, otherwise the system with a matching code or description; what it finds today is shown in brackets. The color field shows the color of the connector.

Gear menu › Property fields

AttributeWhat it doesDefaultExample
TabCommon (fields for all parts of all plug-ins) and one per plug-in; the Block Library opens its own.Block Library–
NameWhat appears in the palette, lists and annotation.–"Room"
KeyFixed name for import and export; fixed after saving.from the nameROOM
TypeText, number, whole number, length (mm), yes / no, choice from a list.textchoice from a list
UnitThe unit after a number.emptykg
ChoiceThe entries of a choice, separated by ;.empty"GF;1st floor;2nd floor"
Applies toThe part groups that carry the field – in the Block Library block and fixture.–fixture only
SuggestionA value the field suggests (empty = none).empty–
always on all parts (otherwise on request)On: the field is on every part of the groups (and in "Common properties"); off: only once it is attached in the palette with "Add field".–on
ask before insertingThe field appears under "Properties of the next block".–on for "construction phase"
offer in listsThe field becomes a column of the block extract and can be chosen when laying out a list.–on
hiddenThe field is disabled (default fields can only be switched off this way).off–
when copyingkeep, clear or renumber – what the value does in a copy.keeprenumber for a tag
Required fieldA note before the extract, lists and IFC if it is empty.offon for "room"
IFC additionally, PCF numberOutput in a standard IFC property set; PCF only in process piping.––

Own fields get the numbers 50 to 99. The catalog applies to all plug-ins – change it with care.

Block wizard

FieldWhat it doesDefaultExample
NameThe block name = file name of the DWG.for a whole, saved drawing its file name, otherwise emptyDouble lavatory 80
Store inThe library folder to save in – only writable ones, never the standard blocks.the first writable oneCustom blocks
SubfolderPath below this folder, separated by /; it is created. If it lies under Apparate, the block also appears on the Fixtures page.Apparate/… from the codeApparate/Waschtische
TypeFixture (with connectors, category plumbing) or Block (geometry only).fixtureblock for a piece of furniture
CodeWC, WT, HWB, DWT, UR, BI, DU, BW, SP, WM, TR, GS, AG, BA – determines the IFC class and suggests the values of the connectors (when leaving the field).WTDU
Fixture typeFor the DU suggestions in Drainage 3D.from the codeshower tray
Description, manufacturer, article number, typeDefault values of the property fields; article number empty = the block name. Text, never calculated.description = name–
W × D × HWidth, depth, height – measured from the selection (height from the insertion point).measured800 × 500 × 850
DrainageCreate a drain.from the codeon
RoutingIn-wall carrier or below ceiling / in the floor – the default of the one drain (switchable in the palette).from the codein-wall carrier
Template horizontalThe Drainage 3D template for horizontal routing.from the codePE – Waschtisch / Wandbecken
In-wall carrier codeThe code of the in-wall carrier template.from the codeWT
Cold water, hot waterCreate one water connector each.from the codeboth
DNThe nominal size of the water connectors.1520

Insert fixtures automatically

SettingWhat it doesDefaultExample
Check box per rowInsert this location.on if a standard fixture is detected–
Standard fixture per rowWhat is inserted; "– do not insert –" = not. Learned for the next plan.the detected onelavatory 60 instead of 50
Type under "A fixture is missing?"Which type the example is.toilet (afterwards the last chosen)shower

What applies from the palette: 2D / 3D switch, connectors only, elevation (free = 0), drainage routing, connector set per fixture.

Properties palette (placed block)

Field (LuaCAD category)What it doesDefaultExample
Width, depth, heightScales the block (X, Y, Z) about the insertion point; the connectors move along in plan.from the DWGwidth 900 instead of 800
WeightValue for lists and IFC.from the DWG25
Distance CW–HWDistance of the water connectors, symmetric about their middle.from the position of the connectors150
Water connector elevationElevation of the water connectors in the fixture.from the position of the connectors550
Water DNNominal size of the water connectors.from the DWG15
DisplayFixture or connectors only.as insertedconnectors only
Connector setThe connector set; pipes follow.as insertedB

The property fields are in their own category below.

Gear menu › further entries

EntryWhat it controls
Drawing units …Units of the fields and of new parts – for all plug-ins, see Drawing units.
Preview window › Show, HideWhether the preview window stands next to the palette. Display, view direction and base point are set in the window itself.
Author …The name in lists, IFC and the clash list – for all plug-ins, empty by default.
Layers › Create all layers of this plug-inCreates missing layers of the standard blocks (for example for an office template); existing ones stay as they are. Custom blocks have no LuaCAD layer.
Getting started activeCards of the pages and the help before inserting for this plug-in on or off.

Typical notes and errors

Message (command line or bottom of the palette)MeaningWhat to do
Block Library: first choose a block in the palette.Insert without a selected block.Click a tile.
Note: the DWG is newer than the block in the drawing …The drawing carries an older state of the DWG.Current Drawing page › Reload block.
The file no longer exists: …The DWG was moved or deleted.Gear menu › Reload library; check the folder.
Block Library: '…' has no 2D parts – the outline from above is inserted as 2D …In 2D the DWG has no floor plan.Draw a floor plan symbol on the layer the message names – or live with the outline.
'…' does not exist in 2D – selection cleared.The switch changed, the selected block has nothing to show in that mode.Choose another block or switch back.
n more only in 3D (switch at the top).The search finds blocks that the switch hides.Change the switch.
No favorites yet – click a star on a tile.The Favorites page is empty.Set a star.
No fixtures – fixtures are in the folder Apparate of a root …No such folder in the library (or all in the other mode).Put custom fixtures in a folder of that name.
No folder set up yet – gear menu › Folders.The library has no root.Gear menu › Folders … › Add.
150 of n blocks – refine the search.Too many hits.Search more precisely or choose a subfolder.
Note: the folder has the scale factor … – a fixture with connectors keeps its size.A fixture from a folder with a factor.Nothing – intended.
Supplied standard blocks – read-only …Create, rename or delete in the standard blocks.Use a folder of your own.
This is a library folder (root) – add, rename and remove in gear menu › Folders.Rename or delete on a root.Gear menu › Folders ….
Renaming did not work – is a DWG from it still open? / Deleting did not work …Windows does not release the folder.Close the DWG, then try again.
Change the size with width, depth and height in the properties.A 3D block was scaled and springs back.Change width, depth, height in the palette.
Mirrored: cold water stays on the right, hot water on the left …A fixture with a CW–HW pair was mirrored.Nothing – intended.
The DWG of this block cannot be found on this computer (…).Reload block or convert 2D to 3D without the DWG.Add the library folder in which it lies.
No fixture was detected in the plan …Detect fixtures in the plan found nothing.Click an example; check the area.
There is nothing I can read there (line, arc, polyline). / I find no shape for this example.The example is not a readable shape.Click another piece of the fixture.
Fixtures from the plan: the plan is drawn in …Plan and preset have different units.Nothing – the fixtures lie on the plan.
No writable root …Block wizard without a folder of your own.Gear menu › Folders … add a folder of your own.
Note: the drainage connector could not be created (Drainage 3D loaded?).Block wizard without Drainage 3D.Open Drainage 3D once, then repeat the wizard.
Block wizard: the drawing is empty …Nothing selected and nothing in the drawing.Draw first.
No field changed.Apply on the Current Drawing page without a change.Change a field.
This is not a fixture with connector sets. / The fixture already has this connector set.Change connector set on the wrong part or without a change.Choose a fixture with several sets.
Layer "…" is locked – part not changed.The block is on a locked layer.Unlock the layer.
Block Library: inserting canceled – details in the log.An error while inserting.Try again; otherwise send the log to support.