LuaCAD Help

Drainage 3D reference

The buttons of the palette

Buttons and tiles that insert something new into the drawing are highlighted or outlined in the color of the plug-in; all others change what is already there. Every button shows a tooltip when you hover over it.

Header and footer (on every page)

Area / buttonEffectMore
LevelLevel for everything you insert from now on; in a project drawing the level of the drawing (locked).Drainage network
System, crosshairSystem for everything new (layer and color); the crosshair takes over the system of a clicked object.Picking the system
Insert (Fittings page only)The chosen fitting or combination to the cursor.Inserting
Generate 3D, Delete 3DOne button for both routing methods – the command recognizes the network from the selection.Generate 3D, Delete 3D
Query and edit propertiesOn General routing only its objects ("(general)"), on In-wall carrier routing only those of the in-wall carrier ("(in-wall carrier)"), otherwise both.Properties
Move, DeleteMove or delete parts, lines or connectors.Move, Delete

General routing page

ButtonEffectMore
Stack down, Stack up, Fixture, Vent (tiles)The connector to the cursor.Inserting connectors
Fixture (list)The template of the Fixture tile.Templates
Fixtures from the Block Library …Open the Block Library on the Fixtures page.Block Library
Insert lineDraw the plumbing line point by point.Plumbing line
Property fields of the next pipeFields every new line gets.–
Slope, % / °Slope of new lines.Slope
EditChange lines of General routing.Edit
Snap to angleBase direction of the angle increment with two clicks.Snap to angle
Delete, Delete allDelete lines; all of the level and system (with a confirmation).Deleting lines
StandardDisplay of the standard (set in the gear menu › Options › Sizing).Standard
DNOnly "no standard": diameter for all pipes.Generate 3D
Reducer: eccentric, concentricHow reducers lie when generating 3D.Reducer
Generate 3D, Delete 3DAs in the footer.Generate 3D

In-wall carrier routing page

ButtonEffectMore
Stack (tile), DN, product lineThe stack of the in-wall carrier with diameter and product line.Stack
Stack dialog box when insertingShow the stack dialog box after placing.Stack
Stack across levels › ToProject only: down to which level below.Across levels
Elevation (of the horizontal branch), value, crosshairAutomatic or fixed invert at the connector.Horizontal branch
Fixture (tile), fixture, product line, DNThe chosen fixture onto the line.Fixture
Connector dialog box when insertingShow the connector dialog box after placing.Connector dialog box
Fixtures from the Block Library …Open the Block Library on the Fixtures page.Block Library
Insert line, slopeDraw the carrier line.Carrier line
Edit, DeleteChange or delete objects of the in-wall carrier.Edit
Standard, Generate 3D, Delete 3DAs on General routing.Generate 3D
Move stack across all levelsThe stacks of the same name go along.Move

Connectors page

ButtonEffectMore
Type (tiles)Stack down/up, fixture, vent, offset, spot elevation.Types
Template, +, pencil, recycle binChoose a template, create (copy), edit, delete.Templates
Stack across levels › ToProject only: how far the stack reaches.Across levels
Show properties before insertingProperty fields before the cursor, the connector dialog box after placing.Connector dialog box
AngleOffset only: angle of new offsets.Offset
Insert …The connector of the chosen type to the cursor (the text names the type).Stack, Fixture
Base point: choose in the previewBase point and distance before inserting.Base point
In the drawing: Edit, DeleteChange or delete inserted connectors.Edit

Fittings page

ButtonEffectMore
Manufacturer, product lineWhere the fittings come from.Product line
Connect two endsPipe, offset or reducer between two free ends.Connect
Method: Single, CombinationOne fitting or several together.Single, Combination
Shape, type, size, automatic, 2nd sizeThe single fitting.Single
ShortenFully shorten a free connector of a fitting.Shorten
Combination, spacing, X dimension, legs, size, 2nd size, outletThe combination.Combination
Insert (footer)The chosen part to the cursor.Inserting

Custom parts page

ButtonEffectMore
Folder, "…"Choose a folder or add, rename, remove folders.Custom part
Show properties before insertingProperty fields before the cursor.Custom part
List, pictureThe parts with a connector; the picture of the selected one.Custom part
Open part, Show in folderOnly for a DWG without a connector.Defining connectors
Top edge, Fixed elevation when inserting freelyElevation of freely inserted parts.Custom part
InsertThe part to the cursor.Custom part
Define connectors, Open folderWizard in the open DWG; folder in Explorer.Defining connectors

Accessories page

ButtonEffectMore
Electrofusion coupling › Insert, DeleteCoupling onto a pipe or removed.Electrofusion coupling
Supports › Insert, Delete, spacing, AutomaticClamps one by one or distributed.Pipe clamps
Wall flange › Insert, DeleteWall flange at a wall penetration.Wall flange
Insulation › Whole network, Single, Network without, Part without, thickness, check boxAdd or remove insulation.Insulation
Manhole › InsertDialog box, then insert freely.Manhole
Trench drain › InsertDialog box, then insert freely.Trench drain

Tools page

ButtonEffectMore
RenumberRenumber a network.Renumber
ReassignLevel, system, product line of many objects.Reassign
Delete drainage networkA whole network (with a confirmation).Delete network
Error markers › Delete allMarkers out of the drawing.Error markers
Check 3DLook for gaps in the 3D.Check 3D
Divide objects across levels …Distribute what reaches across a dividing plane to the levels.Divide across levels
ClashesRule set, Check, list.Clashes

Output page

ButtonEffectMore
Annotation (tiles)Type 1, Type 2, Type 3, Type 2 cut, Qww, spot elevation, stack, fixture, slope, manhole, center to center.Annotation
Edge, Reference, Annotate elevationOnly with the Spot elevation tile.Spot elevation and elevation
Single, All, Move, DeletePlace and change annotations.Annotation
Annotation from template › Annotate, Templates …, Several …, Edit, Check, ReassignAnnotations from template.From template
Detail › Detail, All, Move, DeleteDetails of the nodes.Detail
Parts list, Bill of materials (each with Per network and gear)Lists in the drawing or a file.Lists
Bill of materials across the project …, across xrefs …Lists across several drawings.Across drawings
FittingsWhich fittings get numbers.Fittings
Evaluate visible objects onlyLayers that are off in no list.Lists
Cut listCutting to stock lengths.Cut list

All keys at the cursor

The same key means the same in every plug-in. The action bar shows which keys apply; Shift and Ctrl are never assigned at the cursor.

KeyMeaning in Drainage 3D
Abefore placing: distance to a reference point; while drawing: slope, elevation, wall offset and fixed length; when moving: type a dimension
Spacewhile drawing snap to angle / free; for a connector line snap off/on or (with a distance) next base point; for a fitting show the connectors; when moving free in plan
Lline snap off/on while the Space key switches the base point
Evalues of the next connectors
Rrotate a fitting (connected: next arm); turn the arrow of an in-wall carrier fixture by 90°
Hcenterline elevation of an in-wall carrier fixture; when moving elevation only
L / Qwhen moving along only / across only
Dtype an angle (degrees)
Wpick an angle – always two clicks
Fhold a fitting at the connector
Zpull a fitting away – a pipe in between; back = shorten
Pwhile drawing: take over system and slope of a clicked plumbing line
Ntake over only the system
Arrow keysrotate a fitting by 90°; with a wall offset switch the side
Tabnext solution (Connect two ends)
Enterdone or apply
Esccancel – while drawing, the segments already placed stay; in a dialog-based process (manhole, Reassign) back to the dialog box

The gear menu

The gear menu of Drainage 3D: settings (1), preview window (2), properties (3), layers (4), levels (5), help (6)
The gear menu of Drainage 3D: settings (1), preview window (2), properties (3), layers (4), levels (5), help (6)
EntryEffect
Settings › AttributesAppearance of connectors, plumbing lines, pipes, insulation, clamps, manholes, annotation, spot elevation, slope, item numbers, lists and error markers – each "by system" or its own. Dialog box
Settings › OptionsSnapping, Generate 3D, Sizing, Connectors and fittings, Annotation, Editing. Dialog box
Settings › Angle presetsAngle offset and angle increment of the plumbing line. Settings
Settings › Stock lengths and weldsStock length and weld loss per product line and diameter, joint between stock lengths. Dialog box
Settings › SystemsThe system definitions (drainage application). Settings
Settings › LevelsThe levels of the drawing – the "Level" list at the top of the palette. Settings
Settings › Drawing units …, Snap radius while drawing …Units of new parts; size of the snap circle when drawing the plumbing line. Settings
Preview window › Show, HideThe 3D preview window of the Fittings page; "Show" also brings back a window closed with the cross.
Properties › Property fields …, Property fields of a pipe …, Author …Which fields exist; fields of a whole pipe; the name in lists and IFC.
Layers › Create all layers of this plug-inCreates missing layers; existing ones stay as they are.
Levels › Divide across levels …, Divide objects across levels …, Divide across levels settings …, Check risers …Stacks to the drawings of the levels; dividing plane and switch; check the joints. Across levels
Help › HelpThis online help.
Help › Info, Getting started active, Show getting startedVersion and components; cards and insertion help on/off; the cards of the page shown.
Close paletteClose the palette – the button on the ribbon shows it again.

The LuaCAD settings for all plug-ins are on the ribbon › LuaCAD tab › Info – see LuaCAD settings.

Dialog boxes

Dialog boxWhere it opens
Optionsgear menu › Settings › Options
Attributesgear menu › Settings › Attributes
Stock lengths and weldsgear menu › Settings, Options › Connectors and fittings
Generate 3D – Resultafter "Generate 3D" when there are errors or notes
Plumbing lineEdit or Properties on a plumbing line
Slope, elevation and wall offset while drawingA while drawing a plumbing line
Connectorafter inserting a connector (with the check box), Edit, template
Manhole, Trench drainAccessories page › Insert
Reassign objectsTools page › Reassign
Othersquestions, part properties, systems, levels, angle, snap radius

Options

Presets for all drawings: the values apply to everything inserted or generated afterwards; existing 3D changes only at the next "Generate 3D". The defaults usually fit – change only what you need. Six tabs:

Options, Snapping tab: snap to objects within (1), connect timer (2), connecting to a different system (3), object snap per prompt (4)
Options, Snapping tab: snap to objects within (1), connect timer (2), connecting to a different system (3), object snap per prompt (4)
Options, Generate 3D tab: 90° change of direction (1), fittings (2), electrofusion couplings at the joint (3), branch offset (4); further down in the tab plumbing lines and after generating
Options, Generate 3D tab: 90° change of direction (1), fittings (2), electrofusion couplings at the joint (3), branch offset (4); further down in the tab plumbing lines and after generating
Options, Sizing tab with the default standard DIN EN 12056-2 / DIN 1986-100: standard (1), DN without standard (2), reducers (3), the note on the standard (4), the block for DIN only with building type, calculation of horizontal branches and building drains, minimum building drain, stacks and four check boxes (5)
Options, Sizing tab with the default standard DIN EN 12056-2 / DIN 1986-100: standard (1), DN without standard (2), reducers (3), the note on the standard (4), the block for DIN only with building type, calculation of horizontal branches and building drains, minimum building drain, stacks and four check boxes (5)
Options, Connectors and fittings tab: size of new connectors (1), offset angle (2), stock lengths and welds (3)
Options, Connectors and fittings tab: size of new connectors (1), offset angle (2), stock lengths and welds (3)
Options, Annotation tab: spot elevation and elevation (1), product line short codes (2), connecting line to the part (3); further down in the tab the lists
Options, Annotation tab: spot elevation and elevation (1), product line short codes (2), connecting line to the part (3); further down in the tab the lists
Options, Editing tab: editing/deleting with CAD with four choices (1)
Options, Editing tab: editing/deleting with CAD with four choices (1)

Every setting with its default: gear menu › Options.

Attributes

The Attributes dialog box: cards Connectors, Plumbing line, Pipes and fittings with "by system" (1), helper objects (2), annotation, spot elevation and elevation, slope, center to center (3), item numbers, lists, error markers, text (4)
The Attributes dialog box: cards Connectors, Plumbing line, Pipes and fittings with "by system" (1), helper objects (2), annotation, spot elevation and elevation, slope, center to center (3), item numbers, lists, error markers, text (4)

"By system": layer and color come from the system (gear menu › Systems) – so every system carries its color. Without the check box, the own attribute below applies to all systems. Every button opens layer, color, linetype and lineweight. Every setting: gear menu › Attributes.

Stock lengths and welds

The Stock lengths and welds dialog box: joint butt fused or with an electrofusion coupling (1), product line (2), the table da, stock, catalog, extra per weld (3)
The Stock lengths and welds dialog box: joint butt fused or with an electrofusion coupling (1), product line (2), the table da, stock, catalog, extra per weld (3)

Fused pipes are made up of stock lengths. At the joint of two stock lengths a butt weld is made – the weld loss per weld is deducted from the pipes, the cut list accounts for it – or an electrofusion coupling lies in between. Push-fit product lines have no joint: there "Generate 3D" takes the shortest catalog pipe that is long enough. Every butt weld costs the pipe wall (da – di)/2, half on each side; the table contains only the additional loss per weld. Enter only what differs from the default. Every setting: gear menu › Stock lengths.

Generate 3D – Result

The result, here without errors: verdict (1), Calculated to (2), figures per network (3), the groups per network, here Notes and Sizing (4), Don't show again (5), Close (6)
The result, here without errors: verdict (1), Calculated to (2), figures per network (3), the groups per network, here Notes and Sizing (4), Don't show again (5), Close (6)
PartWhat it shows
Headergreen "3D generated: n drainage network(s) without errors" or orange the number of errors
Calculated tothe standard used for sizing
Figuresper network fittings, pipes (length in m), joints "closed" or "with gaps"
Errors (expanded)red; also as a marker in the drawing
Notes (collapsed)orange; information, for example "More slope" or a part from PE
Sizing per section (collapsed)per section: DN, drain type, ΣDU, Qww in l/s, slope (or vertical), the rule of the standard, number of inlets, path
Network checkonly with gaps: the places
Showshow the place in the drawing (also a click on the row)
Applyonly for a slope suggestion: set the slope on the plumbing line(s) and generate the network again
Don't show againswitch the window off for Drainage 3D (on again: Options › Generate 3D)
Closeclose the window

Plumbing line

Picture coming soonThe Plumbing line dialog box: length and elevations (1), level and system (2), slope with unit (3), diameter, drain type, Carries (4), the values from "Generate 3D" (5)
FieldWhat it does
Length in plan, elevation start/end, ΔZdisplay only
Levelthe level of the line
Systemthe system of the line – sets layer and color
Slope, % / °the slope of the line (takes effect when generating 3D); calculating allowed; at most 100 % (45°)
Diameter"calculate" = "Generate 3D" sizes to the standard; a number = this nominal size (outside diameter in mm) fixed
Drain typefixture drain, branch drain or horizontal branch / building drain – decides the sizing table
Carrieswastewater, storm water or air (vent)
From "Generate 3D"display only: ΣDU, Qww and the built diameter

Slope, elevation and wall offset while drawing

Picture coming soonThe dialog box while drawing: slope (1), "Now …" and elevation with Pick (2), wall offset with amount and side (3), fixed length (4)
FieldWhat it doesDefault
Slope, % / °slope of the next segment; also goes to the palettefrom the palette (2 %)
Elevation, crosshairelevation at the current point: before the first segment the start of the line, afterwards an elevation change (vertical line); the crosshair picks an elevationthe current elevation
Wall offset, sidethe line runs at this distance next to the drawn one; applies only to this run (not in the in-wall carrier)0
Fixed length0 = with the mouse; otherwise OK inserts a segment of this length in the current direction0

Connector

Picture coming soonThe connector dialog box of a fixture: header with picture and type (1), template and short name (2), level and system (3), product line and diameter (4), fittings (5), elevation with top and invert (6), connector with DU and Vented (7)

One dialog box for all types; what does not apply to the choice is hidden. In template mode the name of the template is at the top; level and system come from the palette when inserting.

Section › fieldForWhat it does
Routingfixture from the Block LibraryIn-wall carrier or below ceiling / in the floor – switching places the connector again after OK from the template of the other routing.
Template › namestacks, fixture, ventChoose another template: all values below come from it (position, level and system stay).
Template › short namethe sameShort name in annotations and lists.
Assignment › level, systemall except offset and spot elevationWhat the connector belongs to (offset and spot elevation take it from their line).
Product line › manufacturer, product linestacks, fixture, ventThe pipe product line of the connector.
Product line › diameter or stack pipe, outletthe sameDiameter as a minimum ("Generate 3D" never sizes smaller); the outlet of the stack down ("auto" = from the sizing). Some fittings only exist in fixed diameters.
Fixed size (independent of the calculation)stack downThe stack pipe gets exactly the chosen diameter; if the calculation gives more, a note appears. Default off.
Fittings › continuation abovestacks, fixture, ventWhat follows above the main fitting (nothing, pipe, push-fit coupling, long coupling, formwork box, blockout …), plus extension and the dimensions of a box.
Fittings › main fittingthe sameThe part at the connector: wye, elbows, double 45° bend, straight, floor drain, roof drain, fitting by hand …
Fittings › blockoutwhere selectableProvide a blockout at the main fitting – the dimensions (length, width, height, horizontal/vertical offset, insertion depth) appear below.
Fittings › fully shortenedstack downShorten the main fitting as far as the catalog allows.
Fittings › continuation below, extension or shorteningstack downWhat follows below the main fitting.
Fittings › bottom of fitting instead of invertstack downThe invert elevation applies to the bottom of the lowest fitting.
Fittings › connect without branch offsetstacks, fixture, ventNo raised wye and no offset of two elbows – the outlet goes straight up.
Elevation › top or installation elevation, invertstacks, fixture, ventautomatic (from the slope), from TOS, from BOS (downward), absolute, for stacks also "from the fittings"; plus == exactly, >= at least, <= at most, the value and the crosshair.
Spot elevation › spot elevation here, relative tospot elevationabsolute, from TOS or from BOS with ==/>=/<= and value; top, centerline or invert.
Offset › angle, position, offset, automaticoffset30/45/60/90°; before the connector, exactly at the connector, after the connector; offset fixed or "automatic" from the elevations.
Drainage network › building drainstack downas the inlets (preset), inside the building, outside the building, outside behind a manhole with open flow – effective only under DIN.
Load from above › calculationstack upfloor-level branch, building drain, storm water, horizontal branch, building sewer.
Load from above › pumped discharge line (downward connector)stack upThe inlet is a pumped discharge line.
Load from above › double bendstack upfitting to fitting, 2 × inside diameter, 3 × inside diameter.
Load from above › sum of DU or flow Q, fixtures, individual fixtures …stack upThe load in l/s; or up to ten fixture types with quantity – sum of DU, quantity and largest single DU are calculated from them.
Load from above › Qww, enter load as Qww, K value, continuous flowstack up, building drain/horizontal branchThe load directly as Qww; frequency factor K (0.5/0.7/1.0/1.2); continuous flow in l/s.
Load from above › stack heightstack up, DIN onlyHow high the stack is above this connector (m; empty = up to 10 m): above 10 m a double bend of two 45° elbows with a 250 mm piece in between, above 22 m a bypass.
Ventedfixture, stack upSizing with the table for vented pipes. Default on.
Connector › DUfixtureDischarge unit in l/s (at least 0.05).
Connector › custom partfixtureA DWG instead of the main fitting (list from the folder of the Custom parts page).
Connector › offset, electrofusion coupling, suppliedfixture with floor drain/inletnone/45°/90°; none/at the outlet/at the offset; the generic standard or the version with a product name.
Connector › relief vent (downward connector)ventThe vent as a relief vent.
Axial offsetfixture, ventOffset of the connector along the axis.

The connector dialog box of an in-wall carrier fixture is described under In-wall carrier routing, that of the stack of the in-wall carrier under Stack of the in-wall carrier.

Manhole

The Manhole dialog box, here round without a neck: use, shape (1), inside dimensions (2), top edge with Pick and "Fixed top edge" (3)
The Manhole dialog box, here round without a neck: use, shape (1), inside dimensions (2), top edge with Pick and "Fixed top edge" (3)
FieldWhat it doesDefault
Useinspection chamber, pump sump, silt trap, oil separatorinspection chamber
Shaperound, round with neck (cone), rectangular, rectangular with neck – only the matching dimensions appearround
Wallwall thickness100 mm
Depthinside depth1500 mm
Diameter or lengthround: diameter; rectangular: length (inside)800 mm or 1000 mm
Widthrectangular only800 mm
Neck height, neck diameter or neck length, neck widthwith neck only; the neck must be lower than the depth and narrower than the manhole600 / 625 / 625 mm
Eccentric neck (flush with the wall)round with neck onlyoff
Top edge, crosshairthe installation elevation; when picked it applies as fixed0
Fixed top edgeunchecked, the top edge lies at the elevation of the cursor (drawing plane or object snap)off

The dimensions are in drawing units; the values are kept for the next manhole.

Trench drain

The Trench drain dialog box: outside dimensions (1), installation elevation of the top with Pick (2)
The Trench drain dialog box: outside dimensions (1), installation elevation of the top with Pick (2)
FieldWhat it doesDefault
Length, widthoutside dimensions of the trench drain1200 / 1000 mm
Total heightoutside height, with bottom1500 mm
Wall thicknesslength and width must be greater than twice the wall thickness100 mm
Installation elevation of the top, crosshairthe top; always fixed0

Reassign objects

The Reassign objects dialog box: level, system, product line each with check box, old and new (1), objects (2), connectors (3), plumbing lines (4), drainage network (5)
The Reassign objects dialog box: level, system, product line each with check box, old and new (1), objects (2), connectors (3), plumbing lines (4), drainage network (5)
FieldWhat it doesDefault
Level, system, product line (check box, old → new)What should change; "old" = "all" or only objects with this value, "new" = the new valueoff; new = palette value
Objectsall objects in the area, only parts (pipes, fittings, accessories), only plumbing lines and connectorsall objects in the area (remembered)
Set all spot elevations to "automatic"top and invert of stacks and fixtures to automatic – the elevation comes from the plumbing line againoff
Rebuild slope, value, % / °Set the slope of all selected lines and rebuild the elevations from the stack; then generate the 3D againoff; value from the palette
Set network numberGive all selected objects this network numberoff; the next free one

Other dialog boxes

Dialog boxPurpose
Delete (question)Delete only the selected, Delete 3D or Delete whole drainage network; "Remember answer".
Drainage network with 3D parts changedGenerate 3D again, Delete 3D or only the change; "Remember answer" (for CAD commands).
Different systemA fitting is about to connect to a different system: Connect or Cancel; "Remember answer".
Branch offsetOnly with "ask" (Options › Generate 3D): at the first raised wye of a run the angle with a preview.
Properties (parts)Product line, DN, angle, length, what stays, insulation, system, level – see Properties.
Fixtures of the stack upUp to ten fixture types with quantity for the load from above.
Systems, Levels, Angle presets, Snap radius, Drawing unitsSee Every setting in detail.

Every setting in detail

This section lists every setting of Drainage 3D – on the palette, in the gear menu and in the dialog boxes – with its effect, the default value and an example. Values on the palette apply only to parts you insert afterwards. Settings in the gear menu apply to all drawings. Lengths are typed in drawing units; every number field calculates ("600+400" becomes 1000).

Palette, header

SettingWhat it doesDefaultExample
LevelLevel of new objects; in a project drawing the level of the drawing (locked). Create levels: gear menu › Levels.Not assigned"EG - ground floor"
SystemSystem of new objects – layer and color; only the same system connects.first drainage systemstorm water for the roof drainage

Palette, General routing page

SettingWhat it doesDefaultExample
FixtureTemplate of the Fixture tile.first template"toilet"
Property fields of the next pipeFields for every new plumbing line.no valuesconstruction phase "B"
SlopeSlope of new lines, takes effect when generating 3D.21.5 for a building drain
% / °Unit of the slope; switching converts.%° for a value in degrees
DN (no standard only)Diameter of all pipes.110125
Reducereccentric (top flush) or concentric (centerline continues).eccentricconcentric

Palette, In-wall carrier routing page

SettingWhat it doesDefaultExample
DN (stack)Diameter of the stack pipe (nominal sizes of the product line).11090
Product line (stack)Pipe product line for stack pipe and horizontal branch of the in-wall carrier network.product line of the Fittings pagea fused product line
Stack dialog box when insertingDialog box after placing; unchecked, the last values apply.onoff for many identical stacks
To (stack across levels)Project only: down to which level below.this level onlydown to the basement
Elevation (horizontal branch)automatic, fixed above FF, fixed above TOS, fixed absolute.automaticfixed above TOS, 120
Value, crosshairThe fixed invert at the connector; applies with Enter.0150
FixtureWhich fixture is inserted next.toiletlavatory
Product line (fixture)"as stack" or a fused product line of its own, remembered per fixture.as stack–
DN (fixture)Diameter of the connector, remembered per fixture; fixed for the back-to-back fitting.per template56 for the sink
Connector dialog box when insertingDialog box after placing; unchecked, the last values apply.on–
Slope (line)Slope of new lines of the in-wall carrier in %.21

Palette, Connectors page

SettingWhat it doesDefaultExample
TypeWhich type "Insert …" places.stack downfixture
TemplateTemplate per type (remembered).first template"shower"
ToStack across levels, remembered per direction.this level onlyup to the 3rd floor
Show properties before insertingRemembered per type.onoff when the template fits
Angle (offset)Angle of new offsets (also in the gear menu › Options).45°30°

Palette, Fittings page

SettingWhat it doesDefaultExample
Manufacturer, product lineCatalog of the fittings.first manufacturer, first product linea sound-insulated product line
MethodSingle or Combination.SingleCombination
Shape, typeThe fitting.wyeelbow
SizeOutside diameter.11075
automatic (Single)When connecting, the DN of the connector.onoff for a deliberate reducer
2nd sizeSecond diameter or angle.as size50
CombinationWhich combination.double 45° bendbranch offset wye-elbow
SpacingDistance of the parts.fitting to fitting2 × inside diameter
X dimensionDistance with "manual".0120
LegsL-L, S-L, S-S.L-L (long-long)S-S
Size, automatic (Combination)Diameter; "automatic" as for Single.110, off–
Outletparallel (0°), upward, 45° to the side, 90° to the side.parallel (0°)upward

Palette, Custom parts page

SettingWhat it doesDefault
FolderWhich folder the list comes from.Examples / special parts
Show properties before insertingProperty fields before the cursor.off
Top edgeElevation above FF when inserting freely.0
Fixed elevation when inserting freelyChecked, the elevation above; unchecked, that of the cursor.on

Palette, Accessories page

SettingWhat it doesDefaultExample
Spacing (supports)Largest clamp spacing for "Automatic"; 0 = horizontal 10 × da, vertical 15 × da.01000
Thickness (insulation)Insulation thickness in mm.2540
Insulate when generating 3D and insertingInsulate new pipes and fittings right away.offon for a storm water pipe in a heated space

Palette, Output page

SettingWhat it doesDefaultExample
AnnotationWhich tile "Single" and "All" place.Type 1slope
EdgeTop, centerline or invert (spot elevation and "Annotate elevation").invert (S=)centerline
ReferenceFF, TOS, BOS or absolute.FF (finished floor)absolute
Fittingsonly shortened/cut or all fittings get numbers; switching renumbers.only shortened/cutall fittings
Evaluate visible objects onlyLayers that are off or frozen do not go into the lists.offon

Gear menu › Options

Tab › settingWhat it doesDefaultExample
Snapping › Snap to objects withinHow close to the cursor a part snaps to a free connector, a connector to the end of a line, a line to a line (cm; with "mm" in mm; from 0.5 cm).5 cm10 cm in a dense drawing
Snapping › Connect timerIf connected this long, a fitting is held as with F; Off = only with the key.Off0.8 s
Snapping › Ask when connecting to a different systemQuestion Connect/Cancel; off = connect without a question.on–
Snapping › Object snap per promptPer prompt (plumbing line start, plumbing line further points, inserting connectors, inserting fittings) an object snap of the CAD for the duration of the prompt.as set in GstarCADendpoint and intersection for the start
Generate 3D › Double 45° bend above ΣDUAbove this load a 90° change of direction becomes a double bend of two 45° elbows; a large number = always a 90° elbow.0.11.0
Generate 3D › Spacing of the elbowsautomatic by drain type (building drain 3 × inside diameter, otherwise fitting to fitting), fitting to fitting, 2 × or 3 × inside diameter.automatic by drain type2 × inside diameter
Generate 3D › Below (vent)Up to this load: 90° elbow (long leg), double bend fitting to fitting or with 3 × inside diameter.90° elbow (long leg)–
Generate 3D › 45° change of directionCatalog 45° elbow or cut from a 90° elbow (PE only).catalogcut
Generate 3D › Missing fittings (sound-insulated, welded)If the sound-insulated welded product line does not include a fitting: add it from PE (with a note) or an error marker.add from PEerror marker
Generate 3D › Product line of the drainage networkWhich product line the whole network gets: from the fixtures (most inlets) or from the stack down.from the stack downfrom the fixtures
Generate 3D › General routing / In-wall carrier routing: connect with electrofusion couplingsAt every joint pipe to pipe and pipe to fitting an electrofusion coupling instead of butt fusion (fused only; if the coupling is missing or the pipe is too short, it is fused).offon
Generate 3D › Allow branch offset with 2 × 15° or 2 × 30° elbows … below 17 cmBelow 17 cm difference in elevation first the branch offset of two catalog elbows.on–
Generate 3D › Correct slope automatically up to 5 %If no fitting fits: the branch pipe falls more steeply, at most 5 %, with a note marker; off = error marker.on–
Generate 3D › From 17 cm: raise the wyeautomatic (the 45° wye is raised so far that a 60° elbow, or 30° on the 45° branch, leads exactly into the upper pipe), ask (dialog box with preview at the first such branch), fixed angle.automaticask
Generate 3D › Fixed angleOnly with "fixed angle": none, 30°, 45°, 60°, 75°, 90°.45°60°
Generate 3D › Use from difference in elevationFrom this difference the raised wye; below it straight up or (with "first a fitting") the branch offset of two elbows, then more slope.15 cm20 cm
Generate 3D › Small difference in elevationfirst a fitting, then slope (recommended) or only from the difference, otherwise vertical.first a fitting–
Generate 3D › Raise side wyes by 15°A wye with a horizontal inlet from the side is turned up by 15° – against backflow; the inlet lies slightly higher.offon
Generate 3D › Different system/levelIf a line starts at existing objects in a different system or level: take over from the existing objects, keep the palette (with a note), ask every time.ask every timetake over from the existing objects
Generate 3D › Switch the helper layer … off againAnyone who switched on the helper layer of the hidden lines to look gets it switched off again after the next "Generate 3D".on–
Generate 3D › Show list after generatingThe result window after "Generate 3D".on–
Sizing › StandardDIN EN 12056-2 / DIN 1986-100 (Germany), SN 592 000 (Switzerland), no standard – DN by hand. If a table of the standard is missing in the catalog, the note says so, and "Generate 3D" places an error marker naming the other standard as a way out.DIN EN 12056-2 / DIN 1986-100SN 592 000 for a project in Switzerland
Sizing › DN without standardNominal size of all pipes without a standard.110100
Sizing › Reducerseccentric, crown flush, or concentric (as on the palette). Under DIN an eccentric reducer in the building drain lies flat on bottom; with "concentric" the result names the DIN rule as a note.eccentric–
Sizing › Building type (K)DIN only: frequency factor 0.5 / 0.7 / 1.0 / 1.2 (laboratory, EN only).0.50.7 for a school
Sizing › Horizontal branches/building drainsDIN only: Tables A.3–A.5 (di,min) or Prandtl-Colebrook with the catalog di (often one size smaller).tablesPrandtl-Colebrook
Sizing › Building drain at leastDIN only: DN 100 (recommended) or DN 80 (with a note).DN 100–
Sizing › StacksDIN only: primary ventilation (DIN Table 8) or secondary ventilation (EN Table 12).primary ventilation–
Sizing › Horizontal branches below 2 l/s per Table 7DIN only.on–
Sizing › Single-family house (ventilation)DIN only: the collective main vent need not be one nominal size larger.offon
Sizing › Several lifting stations rarely at the same timeDIN only: largest 100 %, second 40 %, others 10 %.off–
Sizing › Building drains outside behind a manhole with open flowDIN only: full flow per Table A.5.off–
Connectors and fittings › Size of new connectorsSphere diameter of the display per stack down, stack up, fixtures and vents (cm; "per template").per template20 cm
Connectors and fittings › Offset angleAngle of new offsets.45°30°
Connectors and fittings › Stock lengths and welds …Opens the Stock lengths dialog box.––
Connectors and fittings › Allow extended shorteningNot available – shortening goes up to the shortening of the catalog.off (locked)–
Annotation › UnitUnit of the spot elevation and the elevation annotation: cm (whole), m (two decimals), mm (whole).cmm
Annotation › Short code top / centerline / invertCode before the spot elevation.OK, A, SUK instead of S
Annotation › Product line - short codeHow a product line appears in Type 3 annotation and in the lists; empty = its name.empty"PE-HD"
Annotation › Connecting line to the partPer type (Type 1, Type 2, Type 3, Type 2 cut, Qww, spot elevation and elevation, stack, fixture, manhole) a line to the part.onoff for Type 3
Annotation › Lists: Parts list …, Bill of materials …Set the output of the lists.––
Editing › Editing/deleting with CADWhen a part of a network is selected, moved, copied or deleted with the CAD commands: ask every time, only the selected part, always the whole network, always remove the 3D parts of the network. Also applies when deleting from the palette.ask every timealways the whole network

Gear menu › Attributes

Card › buttonWhat it controlsDefault
Connectors › by system, Down, Up, FixturesAppearance of the connectors stack down/up and fixture.by system
Plumbing line › by system, LinesPlumbing line, vent, offset, spot elevation.by system
Pipes and fittings › by system, PE jacket, jacket (sound-insulated product line), insulationBodies and insulation shell (color and transparency).by system
Helper objects › pipe clamp, manhole/trench drain, blockout, formwork box, shaft sleeveeach with "by system".by system
Annotation › frame, text, connecting lineAnnotations of the tiles.by CAD
Spot elevation and elevation › frame, text, connecting lineSpot elevations.frame and line red
Slope › text, arrowSlope annotation.arrow red
Center to center › textCenter-to-center dimension.by CAD
Item numbers › circle, text, lineItem numbers.by CAD
Lists › lines, text, titleTables in the drawing.by CAD
Error markers › error: frame, error: textMarkers of "Generate 3D".red
Text › heightText height of item numbers and annotations (center to center slightly smaller).65 mm
Text › draw connecting linesOn and off for all types; per type in Options › Annotation.on

Gear menu › Angle presets

The Angle presets dialog box: angle offset X-Y and X-Z with Pick (1), angle increment X-Y and X-Z (2)
The Angle presets dialog box: angle offset X-Y and X-Z with Pick (1), angle increment X-Y and X-Z (2)
SettingWhat it doesDefaultExample
Angle offset X-Y / X-ZHow far the angle increment is rotated (plan or vertical); the crosshair picks it with two clicks. "Snap to angle" on the palette does the same.0°12° for an inclined building
Angle increment X-Y / X-ZStep of the increment when drawing the plumbing line.45°15°

Gear menu › Stock lengths and welds

SettingWhat it doesDefaultExample
Joint when generating 3DButt fused (weld loss per weld) or with an electrofusion coupling between the stock lengths.butt fusedelectrofusion coupling
Product lineWhich product line the table applies to (all product lines of the catalog).product line of the Fittings page–
Stock [mm] per daStock length per outside diameter; empty = the longest catalog pipe (column "(catalog)").empty5000
Extra per weld [mm] per daAdditional weld loss per weld (both sides together); the pipe wall always counts already. Locked for push-fit.empty = 02

Gear menu › Systems

The system definitions: the list of systems (1), Edit, Add, Remove and Duplicate (2), Drainage 3D chosen under plug-ins (3); Edit opens the positions of a system
The system definitions: the list of systems (1), Edit, Add, Remove and Duplicate (2), Drainage 3D chosen under plug-ins (3); Edit opens the positions of a system

The system definitions with the drainage application: create and change systems, their appearance per position – stack down, stack up, fixtures, plumbing line and connectors, pipe centerline, PE body, sound-insulated body (by default the same as the PE body – by layer of the system) and insulation (color and transparency, default 80 % by layer). A change "by layer" goes to the layer of the current drawing. More under Systems and System and layer.

Gear menu › Levels

The Levels dialog box: per level code, name and the elevations of the reference levels (1), next to it the preview of the levels with their reference levels (2)
The Levels dialog box: per level code, name and the elevations of the reference levels (1), next to it the preview of the levels with their reference levels (2)

Per level code, name and the elevations of the reference levels TOS, FF, FC, BOS. The levels appear in the Level list at the top of the palette. A change never moves an object. More under Levels and system elevations and Level.

Gear menu › Drawing units and snap radius

The Snap radius while drawing dialog box: diameter of the snap circle (1)
The Snap radius while drawing dialog box: diameter of the snap circle (1)
SettingWhat it doesDefaultExample
Drawing units …In which units new parts go into the drawing and the fields show lengths: automatic (from the drawing), mm, cm, dm, m. Applies to all plug-ins.automaticcm for a drawing in cm
Snap radius while drawing …Diameter of the circle (in 3D the sphere) at the cursor within which drawing the plumbing line snaps to lines and connectors; fixed in the drawing, keeps its size on the sheet when zooming.30 mm60 mm

Connecting fittings and connectors, in contrast, is controlled by "Snap to objects within" (Options › Snapping). See also Drawing units.

Gear menu › Properties, layers, levels, help

EntryWhat it controls
Preview window › Show / HideWhether the 3D preview window of the Fittings page appears; you set display and view in the window itself.
Property fields …Which fields exist (default fields on/off, your own fields) – for all plug-ins.
Property fields of a pipe …Set the fields of a whole pipe; each of its parts takes them over.
Author …The name in lists, IFC and clash list.
Create all layers of this plug-inCreates missing layers; existing ones stay. The drainage connectors of the fixtures lie on the layer of the connectors (not plotted).
Divide across levels settings …Dividing plane (TOS, BOS, FF, FC), level function on/off, question when drawing across a level boundary.
Check risers …Checks the joints of divided risers; result in the issues list.
Getting started activeCards of the pages and insertion help for this plug-in on or off.